Telemetry, timing and OAM
Flow tracker, IFA, QCM, BFD and PTP/BroadSync. Most of these need matching embedded-application firmware; setting a variable alone does not enable a feature.
Set in several SONiC Trident 3 HWSKU files: ptp_bs_fref, ptp_ts_pll_fref.
- appl_param_e2e_scheme_cos
- Type:
- number
- Default:
8
- bfd_control_plane_independence
- Type:
- number
- Default:
1
If the config property is enabled by default (set to 1), if bfd_control_plane_independence is 0, Fw transmit BFD packets with C bit 0, otherwise C bit 1. The default value of the config property is 1 (enabled)
- bfd_cosq
- Type:
- number
- Default:
0
BFD CoS queue
- bfd_dip_lookup_enable
- Type:
- number
- Default:
0
When enabled, destination IP address(DIP) along with source IP address(SIP) is used to de-multiplex BFD session for zero Your-discriminator packets. 0 – Only SIP for de-multiplex BFD session. 1 – SIP and DIP both for de-multiplex BFD session. 2 – Only DIP for de-multiplex BFD session.
- bfd_enable
- Type:
- number
- Default:
0
Enable BFD features
- bfd_encap_memory_size
- Type:
- number
- Default:
0
Memory allocated for BFD encapsulation data (in bytes)
- bfd_feature_enable
- Type:
- number
Enable BFD Feature with bit map fields, lower bits will take precedence, 1st LSB bit is Multi Hop as default, 2nd LSB bit is Micro/Trunk and 3rd LSB bit is Echo mode Feature. Value 0 will disable all the features.
- bfd_ifp_lookup_enable
- Type:
- number
- Default:
0
When this property is configured, IFP will be used for bfd look up instead of HW tables look up. The default value of the config property is 0
- bfd_ignore_l3_host_config
- Type:
- number
- bfd_jitter_disable
- Type:
- number
- bfd_l3_iif_to_vrf_map_enable
- Type:
- number
- Default:
0
Enable/Disable L3IIF to VRF lookup in the FW.
- bfd_num_sessions
- Type:
- number
- Default:
256
Number of BFD sessions
- bfd_over_vxlan_zero_discr_demux
- Type:
- number
- Default:
0
De-multiplex BFDoVxLAN session for zero Your-discriminator packets. 0 – Only VNID for de-multiplex BFD session. 1 – VNID + VTEP SIP both for de-multiplex BFD session.
- bfd_pkt_tx_on_state_change
- Type:
- number
- bfd_remote_discriminator
- Type:
- number
- Default:
0
If the config property is enabled (set to 1), configuring remote discriminator value is always same, not overriding with the learned BFD My discriminator value. The default value of the config property is 0 (disabled)
- bfd_remote_discriminator_reset
- Type:
- number
- Default:
0
Enable/Disable the configuration of resetting remote discriminator variable under certain circumstances such as receiving admin_down or down messages when local session state is UP. The default value of the config property is 0 (disabled)
- bfd_session_down_event_on_create
- Type:
- number
- Default:
0
If this config property is enabled (set to 1), there would be a state change event (State would be down for the endpoint) received after the session is created if we do not receive any packets from the peer within detection_multiplier * 1 seconds. Default value is 0 (disabled)
- bfd_sha1_keys
- Type:
- number
- Default:
0
Number of BFD SHA1 authentication keys
- bfd_simple_password_keys
- Type:
- number
- Default:
0
Number of BFD simple password authentication keys
- bfd_thread_pri
- Type:
- number
Specifies the priority of the bcmBFD thread
- bfd_trunk_auto_tx_port_update_disable
- Type:
- number
- Default:
0
Enable/Disable of updating TX port with RX port behavior of BFD over Trunk endpoints.
- bfd_tx_raw_ingress_enable
- Type:
- number
- Default:
0
Enable/Disable of raw ingress inject of BFD Tx packets from BTE for all sessions which includes support for BFD over LAG, ECMP and except micro, echo BFD
- bfd_use_endpoint_id_as_discriminator
- Type:
- number
- Default:
0
Enable/Disable the configuration of using endpoint index itself as local discriminator for BFD endpoints.If the config property is enabled (set to 1), any value passed in local_discriminator field in endpoint info will be ignored and endpoint index would be used instead. The default value of the config property is 0 (disabled)
- bs_poll_interval
- Type:
- number
Set the debug buffer polling interval in uSec for Broadsync. Default being 1000 uSec.
- clm_enable
- Type:
- number
- Default:
0
- dpll_params
- Type:
- list
Set default parameters for the DPLL command. Comma-Separated-Values. DevSel, CPOL, CPHA, AddrBitOrder, DataBitOrder, AddrWidth, UseBrstBit, UseRwBit
- flow_tracker_intr_enable
- Type:
- number
- Default:
1
- flowtracker_<point>_delay_<granularity|offset>
- Type:
- number
Granularity and offset of the delay values the flow tracker records at one measurement point (
chip,e2e,ipat,ipdt).- Names:
flowtracker_chip_delay_granularity,flowtracker_chip_delay_offset,flowtracker_e2e_delay_granularity,flowtracker_e2e_delay_offset,flowtracker_ipat_delay_granularity,flowtracker_ipat_delay_offset,flowtracker_ipdt_delay_granularity,flowtracker_ipdt_delay_offset
- flowtracker_chip_debug_enable
- Type:
- number
- Default:
0
enable Chip debug functionality. The counters for multiple similar objects will be counted together across the chip. default value: 0 (disabled)
- flowtracker_drop_monitor_enable
- Type:
- number
- Default:
0
Drop monitoring, 0 - Disable, 1 - Enable
- SONiC:
set in 1 Trident 3 HWSKU file;
1
- flowtracker_enable
- Type:
- number
- Default:
0
Enable the flow tracker. Needs the flow tracker embedded-application firmware and exact-match space (
fpem_mem_entries).- SONiC:
set in 1 Trident 3 HWSKU file;
2
- flowtracker_export_fifo_hostbuf_size
- Type:
- number
Number of flowtracker export entries allocated for the FIFO DMA host buffer
- flowtracker_export_fifo_intr_enable
- Type:
- number
- Default:
1
Interrupt vs polled mode for flowtracker fifo dma export
- flowtracker_export_fifo_thread_pri
- Type:
- number
- Default:
100
flowtracker export fifo thread priority; 0 is highest and 255 is lowest
- flowtracker_export_interval_secs
- Type:
- number
- Default:
0
Export interval of the active flows in seconds
- flowtracker_export_interval_usecs
- Type:
- number
- Default:
0
Export interval of the active flows in usecs
- SONiC:
set in 1 Trident 3 HWSKU file;
1000000
- flowtracker_export_ipfix_enable
- Type:
- number
1 - enable MoD periodic counter exports through IPFIX format default value: 0 (disabled)
- flowtracker_flex_state_transition_mode
- Type:
- number
- Default:
0
Specify mode for flexible state transition in flowtracker. 0 – State transition table is pre-defined at SDK initialization. It cannot be modified using APIs after SDK initialization (default). 1 – State transition table is pre-defined at SDK initialization. It can be modified using APIs after SDK initialization. 2 – State transition table is not pre-defined at SDK initialization.
- flowtracker_hostmem_enable
- Type:
- number
Enable host memory access 0 - Disable, 1 - Enable
- flowtracker_indirect_mem_access_timeout_usec
- Type:
- number
- Default:
100000
Indirect flowtracker memory access operation timeout in microseconds
- flowtracker_ipfix_observation_domain_id
- Type:
- number
Ipfix observation domain Id for an observation domain (usually a switch). If IPFIX observation domain needs to be configured at runtime, this config property must not be configured.
- SONiC:
set in 1 Trident 3 HWSKU file;
1
- flowtracker_max_collectors
- Type:
- number
Maximum number of collectors that can be attached to flowtracker groups. Valid only if flowtracker_enable=2 default value: 1
- flowtracker_max_counters_per_flow
- Type:
- number
Maximum number of counters that can be assigned to a single flow. Valid values currently supported are 1, 2 and 4. default value: 1
- flowtracker_max_flows
- Type:
- number
- Default:
0
Maximum number of tracked flows.
- SONiC:
set in 1 Trident 3 HWSKU file;
48000
- flowtracker_unmatched_tuples_size
- Type:
- number
- ibod_fifo_len
- Type:
- number
- ibod_sync_thread_pri
- Type:
- number
- Default:
50
Specifies the priority of the bcmIbodSync thread
- ifa_cc_num_sbus_dma
- Type:
- number
- Default:
2
Maximum number of SBUS DMA. In case of 2 SBUS DMA, 2 SBUS DMA of CMC-1 is used In case of 4 SBUS DMA, 2 SBUS DMA of CMC-0 and 2 SBUS DMA CMC-1 are used default value: 2
- ifa_enable
- Type:
- number
- Default:
0
Enable in-band flow analyzer (IFA) support. Needs the IFA embedded-application firmware.
- SONiC:
set in 1 Trident 3 HWSKU file;
1
- ifa_max_export_pkt_length
- Type:
- number
Maximum possible length of the export packet sent by IFA embedded app.
- ifa_max_vxlan_term_flows
- Type:
- number
Maximum number of IFA VXLAN terminated flows supported by IFA embedded app.
- ifa_rx_pkt_max_length
- Type:
- number
Maximum possible length of the incoming IFA packet.
- ifa_tailstamp_metadata_lns_id
- Type:
- number
LNS format to which the tailstamped metadata is converted prior to insertion in the metadata stack.
- ipfix_hostbuf_size
- Type:
- number
Number of IPFIX export entries allocated for the FIFO DMA host buffer
- ipfix_intr_enable
- Type:
- number
- ipfix_thread_pri
- Type:
- number
- Default:
100
IPFIX export fifo thread priorities; 0 is highest and 255 is lowest
- L1_backup_clk_recovery_port
- Type:
- number
Selects the backup L1 clock recovery port. Choose a non-cpu port that does not have an external phy.
- L1_primary_clk_recovery_port
- Type:
- number
Selects the primary L1 clock recovery port. Choose a non-cpu port that does not have an external phy.
- macsec_enable
- Type:
- number
- Default:
0
Specifies to enable or disable MACSEC feature on the specified port. MACSEC feature might be provided by a PHY device attached to switch port. (Default is to disable MACSEC)
- Forms:
macsec_enable_<port>,macsec_enable_<type>,macsec_enable
- mcs_hostmem_size
- Type:
- number
In supported devices, Part of Host Memory can be allocated and provided to the uC for its internal usage This variable specifies Size in KB. Suffix with _uc0 _uc1 etc.
- mcs_uart_bmp
- Type:
- number
Config to override the default UART number used by the uKernel console User needs to provide the new UART number as a bitmap. i.e bit-0 is UART0 etc. If the config property is set to 0, or if more than one bit is set, firmware will use the default UART. Suffix this config with _uc0 _uc1 etc.
- ptp_<bs|ts>_<pll parameter>
- Type:
- number
Loop and divider parameters of the BroadSync (
ptp_bs_*) and timestamp (ptp_ts_*) PLLs. Set only from the board vendor’s values.- Names:
ptp_bs_ka,ptp_bs_ki,ptp_bs_kp,ptp_bs_mndiv,ptp_bs_ndiv_int,ptp_bs_pdiv,ptp_bs_vco_div2,ptp_ts_ka,ptp_ts_ki,ptp_ts_kp,ptp_ts_pll_mndiv,ptp_ts_pll_n,ptp_ts_pll_pdiv
- ptp_bs_fref
- Type:
- number
Reference frequency in Hz of BroadSync PLL
N:ptp_bs_fref_<N>. Seastone2 files setptp_bs_fref_0andptp_bs_fref_1to 50000000.- Forms:
ptp_bs_fref_<N>- SONiC:
set in 14 Trident 3 HWSKU files;
50000000- On Seastone2:
ptp_bs_fref_0=50000000,ptp_bs_fref_1=50000000
- ptp_cf_sw_update
- Type:
- number
- Default:
0
Control to enable CF update for 1588 packets in software Valid Values: 0x0: CF Update happens in Hardware (default) 0x1: CF Update happens in Software
- ptp_cosq
- Type:
- number
PTP CoS queue
- ptp_ts_pll_fref
- Type:
- number
Reference frequency in Hz of the timestamp PLL. Seastone2 files set 50000000.
- SONiC:
set in 12 Trident 3 HWSKU files;
50000000- On Seastone2:
ptp_ts_pll_fref=50000000
- qcm_flow_enable
- Type:
- number
- Default:
0
Enable QCMv2(Flow Tracking and Queue Congestion Monitoring) embedded app default value: 0 (disabled)
- qcm_ipfix_ntp_timestamp_export_enable
- Type:
- number
- qcm_max_flows
- Type:
- number
Maximum number of flows that can be learnt. default value: 1K
- sw_timestamp_fifo_enable
- Type:
- number
- Default:
1
Get 1588 timestamps from HW register or SW FIFO. If 1(default), timestamps are controlled by soc_feature_timestamp_counter and timestamps are obtained from SW FIFO. If 0, get timestamps directly from HW register.
- telemetry_export_max_packet_size
- Type:
- number
Maximum size of the packet sent by telemetry application. default value: 1500 bytes
- telemetry_max_ports_monitor
- Type:
- number
Maximum number of ports that can be monitored simultaneously by ST app
- timestamp_adjust_<speed>_ns
- Type:
- number
PTP timestamp correction in nanoseconds for ports of one speed (
10gbe,25gbe,40gbe,50gbe,100gbe, …);timestamp_adjust_nsfor all other speeds.- Names:
timestamp_adjust_100gbe_ns,timestamp_adjust_100mbe_ns,timestamp_adjust_10gbe_ns,timestamp_adjust_10mbe_ns,timestamp_adjust_1gbe_ns,timestamp_adjust_20gbe_ns,timestamp_adjust_25gbe_ns,timestamp_adjust_2_5gbe_ns,timestamp_adjust_40gbe_ns,timestamp_adjust_50gbe_ns,timestamp_adjust_ns
- timestamp_tsts_adjust_<speed>_ns
- Type:
- number
One-step timestamp (TSTS) correction in nanoseconds for ports of one speed;
timestamp_tsts_adjust_nsfor all other speeds.- Names:
timestamp_tsts_adjust_100gbe_ns,timestamp_tsts_adjust_100mbe_ns,timestamp_tsts_adjust_10gbe_ns,timestamp_tsts_adjust_10mbe_ns,timestamp_tsts_adjust_1gbe_ns,timestamp_tsts_adjust_20gbe_ns,timestamp_tsts_adjust_25gbe_ns,timestamp_tsts_adjust_2_5gbe_ns,timestamp_tsts_adjust_40gbe_ns,timestamp_tsts_adjust_50gbe_ns,timestamp_tsts_adjust_ns
- ts_counter_combined_mode
- Type:
- number
- Default:
1
Option to program TS counters in common control mode Valid Values: 0x0: Will disable common control mode 0x1: Will enable common control mode (default)
- tsfifo_available_flag
- Type:
- number
- Default:
1
Enable TS FIFO host control
- tsfifo_open_loop
- Type:
- number
- Default:
0
- uc_msg_<setting>
- Type:
- number
Timeouts, retry delay and thread priority of the message channel between the SDK and the embedded ARM applications (BFD, flow tracker, IFA, BroadSync).
- Names:
uc_msg_ctl_timeout,uc_msg_queue_timeout,uc_msg_send_retry_delay,uc_msg_send_timeout,uc_msg_thread_pri,uc_msg_tx_beacon_timeout
- xflow_macsec_secure_chan_to_num_secure_assoc_decrypt
- Type:
- number
- Default:
1
- xflow_macsec_secure_chan_to_num_secure_assoc_encrypt
- Type:
- number
- Default:
1